China ZQ, JZQ Cylindrical Gearbox Speed Reducers - Top Suppliers and Factory for Industrial Applications
Product Features
1
The reducer is used for both forward and reverse operation.
2
The reducer has nine types of transmission ratios, nine configuration types and three low-speed shaft types.
3
The transmission ratios of this type of reducer are:
Standard
48.57 | 40.17 | 31.5 | 23.34 | 20.49 | 15.75 | 12.64 | 10.35 | 8.23
4
The extended model can achieve a larger transmission ratio by adding a high-speed stage:
Extended
317.28 | 291.19 | 243.86 | 223.80 | 191.22 | 163.38 | 141.73 | 121.10 | 92.21 | 81.70 | 65.54
Conditions of Use
⚙️
The circumferential speed of the gear transmission in the reducer shall not exceed 10 meters per second.
🔄
The rotational speed of the high-speed shaft shall not exceed 1,500 revolutions per minute.
🌡️
Working environment temperature ranges from -40℃ to +40℃.
Maintenance
-
1Regularly Check the Oil LevelCheck the oil level once a month or every 500 hours of operation to ensure it is within the specified range.
-
2Regularly Change the Lubricating Oil
- (1) First Oil Change: Carry out the first oil change 36 hours after the first operation to remove metal shavings produced during the running-in period.
- (2) Subsequent Changes: Replace lubricating oil every 2,000–5,000 hours or every 6–12 months. In harsh environments (high temperatures, heavy dust, continuous heavy loads), shorten the oil change cycle.
- (3) Oil Change Method: While the reducer is still warm (lubricating oil has good fluidity), drain the old oil and add new oil to the specified level.
-
3Keep Clean & Ensure Vent Cap Is UnobstructedRegularly clean oil stains and dust from the reducer surface. Inspect and clean the vent cap to prevent blockage.
-
4Fastening InspectionRegularly check whether all installation bolts and connecting parts are loose.
-
5Abnormal Situation Handling⚠️ If a sudden increase in noise, intensified vibration, abnormal temperature rise, or severe oil leakage is detected, stop the machine immediately for inspection. Operation can only resume after the fault has been eliminated.
Detail Pictures
Frequently Asked Questions (FAQ)
Q
What transmission ratios are available for the ZQ/JZQ reducer?
The standard model offers nine transmission ratios: 48.57, 40.17, 31.5, 23.34, 20.49, 15.75, 12.64, 10.35, and 8.23. The extended model adds a high-speed stage to achieve larger ratios ranging from 65.54 up to 317.28.
Q
Can the ZQ/JZQ reducer be used for both forward and reverse operation?
Yes. The ZQ/JZQ reducer is designed to support both forward and reverse operation, making it suitable for a wide range of industrial applications.
Q
What is the maximum allowable rotational speed for the high-speed shaft?
The rotational speed of the high-speed shaft must not exceed 1,500 revolutions per minute (RPM). Exceeding this limit may result in accelerated wear or equipment damage.
Q
What is the recommended operating temperature range for the reducer?
The working environment temperature for the ZQ/JZQ reducer ranges from -40℃ to +40℃. Operating outside this range may affect lubricant performance and the service life of the unit.
Q
How often should the lubricating oil be changed?
The first oil change should be performed 36 hours after initial operation. Subsequent oil changes are recommended every 2,000–5,000 operating hours or every 6–12 months. In harsh environments such as high temperatures, heavy dust, or continuous heavy loads, the oil change interval should be shortened accordingly.
Q
What should I do if the reducer shows abnormal noise, vibration, or oil leakage during operation?
If any abnormal symptoms are detected — including sudden noise increase, intensified vibration, unusual temperature rise, or severe oil leakage — stop the machine immediately and conduct a thorough inspection. Do not resume operation until the root cause has been identified and the fault fully resolved.